Product Specs
Generator Set Specifications
- Minimum Rating
- 200 kVA
- Maximum Rating
- 220 kVA
- Emissions/Fuel Strategy
- Non Regulated
- Voltage
- 220 to 415 Volts
- Frequency
- 50 Hz
- Speed
- 1500 rpm
- Duty Cycle
- Standby, Prime
Engine Specifications
- Engine Model
- Cat® C7.1
- Bore
- 4.1 in
- Stroke
- 5.3 in
- Displacement
- 427.8 in³
- Compression Ratio
- 16.0:1
- Aspiration
- Turbocharged, Air to Air Aftercooled
- Fuel System
- Inline
- Governor Type
- Electronic
Generator Set Dimensions
- Length - Maximum
- 98.4 in
- Width - Maximum
- 52 in
- Height - Maximum
- 64 in
- Dry Weight - Genset (maximum)
- 3816 lb
Standard Equipment
-
- Control Panel
-
- GCCP Control panel
-
- Alternator And Alternator Attachments
-
- 12 Leads
- IP23 Protection
- Voltage regulator (single phase sensing)
- Tower panel, IP22, bottom cable entry
- Segregated low voltage (AC/DC) wiring panel
- Circuit breaker, IEC, 3 Pole, mounted in tower panel
-
- Governing System
-
- Electronic governing system
-
- Cooling System
-
- Radiator and cooling fan with guards
- Coolant drain line with valve
- Fan drive, battery charging alternator drive
- Caterpillar extended life coolant
-
- Air Inlet System
-
- Air cleaner; light duty with disposable element
-
- Exhaust System
-
- Stub pipe, gaskets, raincap & SAE exhaust flange
- Industrial silencer
-
- Fuel System
-
- Standard open set fuel tank/base
-
- Lube System
-
- Lubricating oil
- Oil drain line with valve
-
- Mounting System
-
- Captive linear vibration isolators
- Lifting provision and drag points
- Termination points for coolant and lube oil drain lines
-
- Starting/charging System
-
- 12V Battery with rack & cables
-
- General
-
- Engine and alternator pre-paint, Caterpillar yellow
Attachments
-
- Control Panel
-
- GCCP Control panel
- Earth fault and earth leakage
- Emergency E-Stop with security key
- 4 Pole Circuit breaker
- Voltage and speed adjust potentiometer
-
- Alternator And Alternator Attachments
-
- LC Frame alternator
- LC/M Frame alternator
- Space heater
- Permanent magnet excitation (PMG)
- Automatic voltage regulator
- Quadrature droop kit
-
- Enclosures
-
- Level 1 and Level 2 sound attenuated enclosures
- Single point lifting frame
- Rental pack
- SBOX - CEE form sockets
-
- Alarms And Shutdowns
-
- Common alarm
- Overload shutdown
- Low coolant level shutdown
- Low coolant temperature alarm
- Low fuel level alarm and shutdown
- High fuel level alarm
-
- Engine
-
- Jacket water heater
- Battery charger
-
- Fuel System
-
- Bunded base tank sized for a minimum of 12 hours running with 110% spill protection
-
- Exhaust System
-
- Residential silencer 25 dBA
-
- Certification
-
- Certificate of Conformance
- EAC Certification
-
- Extended Service Coverage
-
- 3, 4, 5 and 10 Years