Product Specs
Generator Set Specifications
- Standby Rating
- 2000 kVA
- Prime Power Rating
- 1825 kVA
- Emissions/Fuel Strategy
- Low Fuel Consumption
- Voltage
- 380 to 415 Volts
- Frequency
- 50 Hz
- Speed
- 1500 rpm
- Duty Cycle
- Standby, Mission Critical, Prime, Continuous
- Maximum Rating
- 2000 kVA
- Minimum Rating
- 1600 kVA
Engine Specifications
- Engine Model
- 3516 TA, V-16, 4-Stroke Water-Cooled Diesel
- Bore
- 6.69 in
- Stroke
- 7.48 in
- Displacement
- 4210.64 in³
- Compression Ratio
- 13.0:1
- Aspiration
- TA
- Fuel System
- Mechanical unit injection
- Governor Type
- Woodward
Generator Set Dimensions
- Length - Maximum
- 234.4 in
- Width - Maximum
- 90 in
- Height - Maximum
- 94.9 in
- Dry Weight - Genset (maximum)
- 33840 lb
Standard Equipment
-
- Air Inlet System
-
- Air cleaner; single element canister type
-
- Governing System
-
- ADEM A3
-
- Control System
-
- Auto/start/stop control
- EMCP 4.2B
- Environmental sealed front face
- Generator mounted - rear facing
- Speed adjust
- 24 Volt DC operation
- Generator set packages include Caterpillar's voltage regulator
- Text alarm/event descriptions
- Emergency stop pushbutton
- Engine cool-down timer
- Engine cycle crank
- IVR includes reactive droop capability, 3-phase voltage sensing, KVAR / PF modes, RFI suppression, min / max exciter. Limiter and exciter diode monitor
- Controls:
- Alarm acknowledge
- Lamp test
- PLC functionality
- Load histogram feature
- 3 Analog inputs
- Operating hours
- Serial annunciator module data link
- Digital indication for:
- 4 programmable relay outputs (Form A)
- ATAAC - 3516E package radiators shipped installed
- Communications:
- Customer data link (Modbus RTU)
- Reverse reactive power (kVAr) (32RV)
- Accessory module data link
- Number of I/O varies on options selected
- RPM
- Overcurrent (50/51)
- Customizable screens -0 True RMS AC metering, 3-phase, +/-2% accuracy
- 1 programmable relay outputs (Form C)
- 1 programmable digital outputs
- Cat connect
- 6 Customer programmable digital inputs
- Certified standard PGS provided
- Volts (L-L & L-N)
- Coolant temperature
- Oil pressure (psi, kPa or bar) - Coolant temperature - Volts (L-L & L-N) - Frequency (Hz) - Amps (per phase & average) - Power factor (per phase & average) - kW (per phase, average & percent) - kVA (per phase, average & percent) - kVAr (per phase, average & percent) - kW-hr (total) - kVAr-hr (total)
- Frequency (Hz)
- kVA (per phase, average & percent)
- Amps (per phase & average)
- Power factor (per phase & average)
- kVAr (per phase, average & percent)
- kW (per phase, average & percent)
- kW-hr (total)
- kVAr-hr (total)
- Failure to start (overcrank)
- Emergency stop
- Overspeed
- Warning/shutdown with common LED indication of shutdowns for:
- High coolant temperature
- Low oil pressure
- Programmable protective relaying functions
- Low coolant level
- Low coolant temperature
- Generator phase sequence
- Over/under frequency (81 o/u)
- Over/under voltage (27/59)
- Reverse power (kW) (32)
-
- Exhaust System
-
- Dry exhaust manifold
- Flanged faced outlet(s)
-
- Fuel System
-
- Fuel priming pump
- Flexible fuel lines - shipped loose
- Secondary fuel filters
- Fuel cooler; not included with packages without radiator
-
- General
-
- Right hand servicing
- Flywheel and flywheel housing - SAE No. 00
- Caterpillar yellow with high gloss black rails and radiator
- SAE standard rotation
-
- Generator And Attachments
-
- Winding temperature detectors
- Busbar connections, right side extension box, bottom cable entry
- Permanent magnet excitation (PMG)
- NEMA Class H insulation system, Class H temperature rise at 40C ambient (125C prime/150C standby
- Busbar connections, top center mounted, top cable entry
- Anti-condensation space heater
- NEMA standard hole pattern
- NEMA Class H insulation system, Class H temperature rise at 40C ambient (125C prime/150C standby)
- Low voltage:
- Winding temperature detectors
- Form wound
- Medium voltage:
- Winding temperature detectorsle pattern
- NEMA standard hole pattern
- Six lead
- Form wound
- Internal excitation (IE)
- 3 Phase brushless, Salient pole
- Random wound
- Busbar connections, top center mounted, top cable entry
- Class H insulation, Class F temperature rise at 40C ambient (105C prime/130C standby)
- High voltage:
-
- Literature
-
- Parts book
-
- Lubrication System
-
- Oil drain lines and valve
- Lubricating oil
- Gear type lube oil pump
- Integral lube oil cool
- Fumes disposal
- Oil filter, filler and dipstick
-
- Mounting System
-
- Rails - Engine/generator/radiator mounting
- Rubber anti-vibration mounts - shipped loose
- Anti-vibration mounts (shipped loose)
-
- Starting System
-
- 24 Volt electric starting motor
- 45 Amp Charging alternator
- Battery disconnect switch
- Battery and battery rack w/cables
Attachments
-
- Control System
-
- Local annunciator module: [ ] NFPA 110 [ ] Custom
- EMCP 4.3, EMCP 4.4
-
- Air Inlet System
-
- Dual element air cleaner
- Single element filter
-
- Cooling System
-
- Water level switch gauges
- Coolant
- Standard ambient radiators
- Standard ambient ATAAC radiators
- Optional installed ATAAC radiators
- Optional installed radiators
-
- Engine Options
-
- Starting aids: [ ] 220V 50 Hz Jacket water heater
- Air cleaner: [ ] Single element air cleaners [ ] Dual element air cleaners [ ] Heavy duty air cleaners
- Batteries: [ ] Standard (1400 CCA) [ ] Heavy Duty (2800 CCA)
- Starting motors: [ ] Standard [ ] Heavy duty
- Muffler: [ ] Industrial Grade
-
- Crankcase System
-
- Explosion relief valves
- Ventilation system
- No explosion relief valves
-
- Alternators
-
- Temperature rise (over 40°C ambient): [ ] 150°C [ ] 125°C [ ] 105°C [ ] 80°C
-
- Exhaust System
-
- Y Adapters
- Exhaust offset
- Tier 4 dosing cabinet
- Flexible fittings
- Elbows
- Clean emission parts
- Tier 4 clean emissions module
- Flanges
- Tier 4 clean emission MOD Kits
- Mufflers
- Flange and exhaust expanders
-
- Fuel System
-
- Fuel priming pumps (Tier 4) - Manual or electric
- Primary fuel filter
-
- General
-
- UL 2200 package
- US aid emblem
- Special paint (Colors other than Caterpillar yellow or high performance paints)
- Seismic Certification per applicable building codes: IBC 2000, IBC 2003, IBC 2006, IBC 2009, CBC 2007
- The following options are based on regional and product configuration:
-
- Power Termination
-
- Circuit breaker operation: [ ] Electrical
- Circuit breaker trip unit: [ ] LSI [ ] LSIG [ ] LSIG-P
- Power termination: [ ] Busbar [ ] Circuit breaker
- Circuit breaker rating: [ ] 2000A [ ] 2500A [ ] 3200A [ ] 4000A
-
- Generators And Attachments
-
- Low / Medium voltage: 380, 440, 480, 600 volts, 3 phase 1800 rpm. RW, IE, No. of Leads = 6, Pitch = .6667: 1600 Frame
- Low / Medium voltage: 380, 416, 440, 480, 600, 2400, 4160 Volts, 3 Phase 1800 RPM, FW, PM, No. of Leads = 6, Pitch = .6667: 1600, 1800 Frame
- Space heater
- Differential current transformers (DCT)
- Low / Medium voltage: 380/400/415 volts, 3 phase 1500 rpm. RW, PM, No. of Leads = 6, Pitch = .6667: 1600 and 1800 Frames
- Generator conversion
- Differential current transformers (DCT) 8.7 kV and 15 kV classes
- Thermostat for space heater
- Alternator air cleaner
- High voltage: 12470, 13200, 13800 volts, 3 phase 1800 rpm,FW, PM, No. of Leads = 6, Pitch = .6667: 2700, 3000 Frame
- High voltage: 6300, 6600, 6900 volts, 3 phase 1800 rpm, FW, PM, No. of Leads = 6, Pitch = .6667: 2700, 3000 Frame
- Low / Medium voltage: 380/400/415 volts, 3 phase 1500 rpm. RW, IE, No. of Leads = 6, Pitch = .6667: 1600 Frame
-
- Extended Service Contract (esc)
-
- Extended Service Contract (ESC): [ ] 2 Year [ ] 3 Year [ ] 5 Year
-
- Instrumentation
-
- Pyrometer and thermocouples
-
- Lubrication System
-
- Lube oil in standard sump
- Prelube pumps
- Oil level regulator
-
- Mounting System
-
- Puck style low efficiency isolators
- Spring type vibration isolators
- IBC vibration isolators
-
- Power Connections
-
- Right side power connections
- Ground cables between generator and terminal box
- 2700 Frame, four lead, four terminal
- Neutral ground connections
- Rear power connections
- Low voltage Circuit breakers
- Center post busbars
- Left side power connections
-
- Special Tests / Reports
-
- PGS Test report @ 0.8 power factor
- PGS Test report @ 1.0 power factor
- Canadian Standards Association certification
- Standard engine test charge
- IBC Certification
- Generator set fuel consumption test
- OSHPD Certification
- Generator test report
- Torsional vibration analysis reports
- Fuel consumption test
-
- Starting And Charging
-
- 10, 20, 35 and 50 Amp Battery chargers
- 24 Volt battery set - Dry
- Electric starting motors
- Air starting motors
- Starter cover
- Engine barring device
- Air pressure regulator
- Jacket water heaters
-
- Extended Service Coverage
-
- Platinum, Gold and Silver coverage