Product Specs
Generator Set Specifications
- Maximum Rating
- 125 ekW
- Minimum Rating
- 125 ekW
- Emissions/Fuel Strategy
- U.S. EPA Cert., Tier 3
- Voltage
- 208 to 600 Volts
- Frequency
- 60 Hz
- Speed
- 1800 rpm
- Duty Cycle
- Standby
Engine Specifications
- Engine Model
- C7.1 I-6, 4-Cycle Diesel
- Bore
- 4.1 in
- Stroke
- 5.3 in
- Displacement
- 428 in³
- Compression Ratio
- 16.7:1
- Aspiration
- Turbocharged, Air to Air Aftercooled
- Fuel System
- Electronic, Common Rail
- Governor Type
- ADEM™A4
Generator Set Dimensions
- Length - Maximum
- 103.7 in
- Width - Maximum
- 51.2 in
- Height - Maximum
- 52.2 in
- Dry Weight - Genset (maximum)
- 3099 lb
Standard Equipment
-
- Air Inlet System
-
- Air cleaner; light duty with disposable element
-
- Control Panels
-
- GCCP 1.2 Control panel
-
- Cooling System
-
- Fan drive, battery charging alternator drive
- Coolant drain line with valves
- Caterpillar extended life coolant
- Radiator and cooling fan with guards
-
- Generator And Generator Attachments
-
- Segregated low voltage (AC/DC) wiring panel
- IP23 Protection
- Circuit breaker, IEC, 3 pole, mounted in tower panel
- Voltage regulator (single phase sensing)
- Tower panel, IP22, bottom cable entry
- 12 Leads
-
- Exhaust System
-
- Stub pipe, gaskets, raincap and SAE exhaust flange for customer use - shipped loose
-
- Fuel System
-
- Base, formed steel with single wall integral 24-hour fuel tank
- Standard open set fuel tank/base supplied
-
- Lube System
-
- Oil drain line with valve
- Lubricating oil
-
- Mounting System
-
- Termination points for coolant and lube oil drain lines
- Includes lifting provision and drag points
- Captive linear vibration isolators between base and engine-generator
-
- Starting / Charging System
-
- 24V battery with rack and cables
-
- Governing System
-
- Mechanical and electrical governing system - model dependent
-
- General
-
- Engine and alternator pre-paint, Caterpillar yellow
Attachments
-
- Alternator System
-
- Alternator removal
- Optional LC Frame alternator
- R Frame auxiliary winding: R2273L4 SE aux alt 07, aux alt 08 and aux alt 10
- Permanent magnet excitation (PMG)
- Anti-condensation heater
- 3 Phase sensing
- Quatrature droop king
-
- Circuit Breakers
-
- Padlockable breaker device
- 4 Pole 250A, 400A and 630A Circuit breakers
-
- Control Panel Options
-
- Battery charger
- Control panel heater
- Earth fault (2 wire only)
- Volt free contacts
- Emergency stop with key
- Speed adjust potentiometer
- Earth leakage (2 wire only)
- Overload shutdown via breaker
- Speed adjust contacts
- Panel mounted audible alarm
-
- Control System
-
- Volt free contacts for generator set running
- Volt free contacts for common alarm
- Static battery charger
- GCCP 1.2
-
- Cooling System
-
- Coolant heater
- Low coolant temperature
- Low coolant level shutdown
-
- Enclosures
-
- Sound attenuated level 2 enclosure
-
- Mounting Options
-
- Silencer installation kit
- Residential silencer
- Battery removal
- Industrial silencer removal
- Electronic governor
-
- Fuel Systems
-
- Low fuel level shutdown
- Open set narrow tankbase
- Skidbase for CALG enclosure sets
- DEFRA bunded fuel tank
- Low fuel level alarm
- Compact skidbase for open sets
- High fuel level alarm
-
- Test Reports
-
- PGS Test report @ 0.8 power factor
- PGS Test report @ 1.0 power factor
-
- General
-
- Stone guards/radiator trans flange
-
- Global Certifications
-
- Certification for CIS
-
- Power Termination
-
- Circuit breaker, IEC, 4 pole
-
- Accessories / Miscellaneous
-
- Packing case - compact set
- Packing case - canopied set